To complete the copy, follow the procedure as indicated
- Start copying until the "Check operation" screen
- Press the menu button at the top right to enter manual recording as in the image below
- Move both sliders to 4 seconds
- Press the " SW1" button on the control unit
- When the " DL1" LED on the board flashes, press the " Transmit source code " button in the application, the " DL1" LED will remain lit steadily.
- Press the " Transmit opening signal " button in the app
- To exit storage mode, wait until it is full
turning off the LED.